Air Handler Hot Water Coil Piping
System technology from viessmann the benefits at a glance.
Air handler hot water coil piping. Williams standard coil has the hot water coil located in the reheat position. A malfunction anywhere in this system can cause an air handler to not dispose of water properly and result in water overflowing onto the floor. If you opt to not counter flow a chilled water coil you ll have to reduce the coil s overall performance by a certain percentage. 4 vh fan coil 2 way.
An example of a typical hot water ahu coil piping is shown below. 2 table of contents. There are some residential air handlers that use either a hot water heater or a boiler for a hot water coil located in the air handling unit. 5 vh fan coil 3 way.
Common problems encountered when working on these air handlers include. Flyer pdf 778 kb benefits. Ideal cooling and dehumidification when combined with an evaporator coil and air conditioning unit. A very standard design we see every day.
Normal problems in hot water chilled water air handlers include condensate leaks dirty coils control malfunctions water flow problems and control piping and airflow design problems. The return temperature to the boilers will be 140 f. Variable air volume systems chilled hot water applications. 2 table of contents general notes and legend.
Ah av. The rinnai hydronic air handler systems connects seamlessly to select rinnai tankless water heaters to deliver efficient home heating and domestic hot water simultaneously in one complete system. 6 vh fan coil 3 way with ball valve in bypass. 28 115 mbh.
7 guide specifications 7 component specifications manual ball valve with. Quiet performance as a result of a fully. The air passes over the coil and picks up heat from the coil and hot water inside the coil. An air handler that is leaking water on the floor may be the result of a few issues.
That percentage reduction varies based on each coil s unique dimensions but a reliable estimate is a loss of 8 12. 3 piping package code descriptions diagrams vav products and hl hp vf and vl fan coils. Another set of pipes is dedicated to hot water generally kept between 150 degrees f and 200 degrees f. Water is produced as a byproduct of the cooling system and typically drains away from the house through a hose or pipe.
In the case of a steam coil the steam trap could be a problem. The pipes run to air handlers which use the chilled or hot water to change the air temperature. 1 5 5 tons. On a call for heat a circulator pump kicks on along with the blower.
Ah008w2b40 w2 indicates a two pipe water coil ah008w4b40 w4 indicates a four pipe water coil ah008w2b40 40 indicates four row chilled water. One set is dedicated to chilled water kept between 60 degrees f and 40 degrees f. Simply piping the coils in the correct manner from the beginning would seem to be the easiest and most cost effective solution.