Air To Water Heat Exchanger Design Calculations
Q m h c ph t hin t hout m c c pc t cout t cin where.
Air to water heat exchanger design calculations. Following is the equation to be used. This type of heat exchangers offers a great flexibility to meet almost any service. Water to air heat exchanger. Calculation assumes true counter flow.
This calculator will help determine which exchanger has enough heat transfer capacity for your system. Calculation of heat exchanger. Heat exchanger calculations with the heat exchanger design equation require a value for the heat transfer rate q which can be calculated from the known flow rate of one of the fluids its heat capacity and the required temperature change. Carlson heat exchanger fluid to fluid sizing calculator.
The overall heat transfer coefficient. Fluid properties are used at the average temperatures. The heat exchanger design equation q u a δtlm can be used to determine the required heat transfer area a for a heat exchanger. Air is assumed to be dry at atmospheric pressure and at zero elevation.
Enter the btu requirement temp in temp out and gpm are shaded for hot and cold enter two of the three shaded portions for hot enter two of the three shaded portions for. Acfm is assumed to be at the average air temperature. Shell and tube heat exchanger type exchangers are used in many process industries as well as nuclear power stations as condensers steam generators in pressurised water reactor power plants and feed water heaters. A domestic radiator where hot water gives up its heat to the ambient air may be described as a heat exchanger.
Only sensible heat transfer occurs. When btu requirement is known most applications. The overall heat transfer coefficient u and the log mean temperature difference for the heat exchanger δtlm based on the values of several input parameters. Consider a parallel flow heat exchanger which is used to cool oil from 70 c to 40 c using water available at 30 c.
Air cooled heat exchanger sizing does preliminary estimation of finned area plot size total fan power and air outlet temperature checalc chemical engineering calculations to assist process plant operation and maintenance engineers. The heat transfer area can be calculated after values have been determined or estimated for the required heat transfer rate q. Air conditioning and refrigeration systems. Liquids are considered incompressible.
Similarly a steam boiler where combustion gases give up their heat to water in order to achieve. They are also used in many other applications i e. The outlet temperature of the water is 36 c. The rate of flow of oil is 1 kg s.
Fluid temperature ranges from 40 f to 200 f. The term heat exchanger strictly applies to all types of equipment in which heat transfer is promoted from one medium to another. Arkansas state university jonesboro.